Samsung iDCS 100 M2. Параметры соединения и формат данных SMDR/CDR


Данные ниже соответствуют только программе Advanced PBX Data Logger и могут быть не применимы для других программных продуктов.

Samsung OfficeServ/iDCS programming codes

MMC830
IP Address - e.g. 192.168.01.20
Subnet Mask - usually 255.255.255.0 (same network)
LAN Gateway - e.g. 192.168.1.3
Card Reset - YES

MMC 829
[01]. SMDR - Destination set to PC (Port 5100)
[02]. UCD Report - Destination set to PC (Port 5101)
[06]. Periodic UCD - Destination set to PC (Port 5105)

then Update LAN - YES

MMC 725. Turn on all options except Page header

MMC 210
PERI UCD Report - On
PERI UCD SIO - Off

MMC 501. PERI UCD Report. Set to 03 sec


MMC 722. Assign ACD Group Supervisor key to keyset(s) and set up auto clearing of data at 23:59pm each night, and auto-printing every hour. (If you do not do this, then the Reports in ACD Supervisor will not work).

Configuring PBX Data Logger

Our software should work in the TCP client mode. It means that our software will initiate connection with the PBX and the PBX will work as a server. Add one or several PBX IP addresses here (the IP address of the Samsung iDCS). The port number should match the port that you have defined within the PBX (5100 in the example below).

TCP Client Mode - Samsung iDCS
5100
5100

Данные, извлекаемые PBX Data Logger

ОписаниеТип данныхИмя колонки
РасширениеstringEXT
COstringTRUNK
Время звонкаdatetimeCALL_TIME
Длительность звонкаdatetimeCALL_DURATION
Длительность звонка (с)integerCALL_DURATION_S
Тип звонкаstringCALL_TYPE
НаправлениеstringDIRECTION
ТелефонstringDIALED_PHONE
Вызывающий телефонstringCALLER_PHONE
AccstringACC

Замечание: Продукты и компании, указанные здесь используются только для обозначение и идентификации и могут быть торговыми и/или зарегистрированными марками соответствующих компаний.