Смещение MODBUS | Описание | Ед. изм. | Тип данных |
40005 | Manufacturer | | string(32) |
40021 | Device model | | string(32) |
40037 | Options | | string(16) |
40045 | Sw version of inverter | | string(16) |
40053 | Serialnumber of the inverter | | string(32) |
40069 | Modbus device address | | word |
40072 | Ac сумма ток value | | single |
40074 | Ac фаза A ток value | | single |
40076 | Ac фаза B ток value | | single |
40078 | Ac фаза C ток value | | single |
40080 | Ac напряжение фаза ab value | | single |
40082 | Ac напряжение фаза bc value | | single |
40084 | Ac напряжение фаза ca value | | single |
40086 | Ac напряжение фаза A to neutral value | | single |
40088 | Ac напряжение фаза B to neutral value | | single |
40090 | Ac напряжение фаза C to neutral value | | single |
40092 | Ac мощность value | | single |
40094 | Ac частота value | Hz | single |
40096 | Кажущаяся мощность | VA | single |
40098 | Реактивная мощность | VAr | single |
40100 | Коэффициент преобразования мощности | | single |
40102 | Ac lifetime energy production | Wh | single |
40108 | Dc мощность value | | single |
40120 | Event flags (bits 0 31) | | dword |
40122 | Event flags (bits 32 63) | | dword |
40124 | Vendor defined event flags (bits 0 31) | | dword |
40126 | Vendor defined event flags (bits 32 63) | | dword |
40128 | Vendor defined event flags (bits 64 95) | | dword |
40130 | Vendor defined event flags (bits 96 127) | | dword |
40133 | Length of nameplate model | | word |
40135 | Continuous мощность выход capability of the inverter | | word |
40137 | Continuous volt ampere capability of the inverter | VA | word |
40139 | Continuous var capability of the inverter in квадрант 1 | var | smallint |
40142 | Continuous var capability of the inverter in квадрант 4 | var | smallint |
40144 | Maximum rms ac ток level capability of the inverter | | word |
40146 | Minimum коэффициент преобразования мощности capability of the inverter in квадрант 1 | | smallint |
40149 | Minimum коэффициент преобразования мощности capability of the inverter in квадрант 4 | | smallint |
40151 | Nominal energy rating of storage device | Wh | word |
40155 | Maximum rate of energy transfer into the storage device | | word |
40157 | Maximum rate of energy transfer out of the storage device | | word |
40161 | Length of basic settings model | | word |
40162 | Setting for maximum мощность выход. Default to i_wrtg | | word |
40163 | Напряжение at the pcc | | word |
40164 | Offset from pcc to inverter | | smallint |
40167 | Setpoint for maximum кажущаяся мощность. Default to i_vartg | VA | word |
40168 | Setting for maximum реактивная мощность in квадрант 1. Default to varrtgq1 | var | smallint |
40171 | Setting for maximum реактивная мощность in квадрант 4 default to varrtgq4 | var | smallint |
40173 | Setpoint for minimum коэффициент преобразования мощности value in квадрант 1. Default to pfrtgq1 | | smallint |
40176 | Setpoint for minimum коэффициент преобразования мощности value in квадрант 4. Default to pfrtgq4 | | smallint |
40193 | Length of measurements_status model | | word |
40227 | Bit mask indicating which inverter controls are токly активная | | dword |
40229 | Source of time synchronization | | string(8) |
40233 | Seconds since 01 01 2000 00:00 utc | | dword |
40239 | Length of immediate controls model | | word |
40240 | Time window for connect/disconnect | | word |
40241 | Timeout period for connect/disconnect | | word |
40243 | Set мощность выход to specified level | | word |
40244 | Time window for мощность limit change | | word |
40245 | Timeout period for мощность limit | | word |
40246 | Ramp time for moving from ток setpoint to new setpoint | | word |
40248 | Set коэффициент преобразования мощности to specific value cosine of angle | | smallint |
40249 | Time window for коэффициент преобразования мощности change | | word |
40250 | Timeout period for коэффициент преобразования мощности | | word |
40251 | Ramp time for moving from ток setpoint to new setpoint | | word |
40254 | Реактивная мощность in percent of i_varmax | | smallint |
40256 | Time window for var limit change | | word |
40257 | Timeout period for var limit | | word |
40258 | Ramp time for moving from ток setpoint to new setpoint | | word |
40265 | Length of multiple mppt inverter extension model | | word |
40270 | Global events | | dword |
40272 | Number of modules | | word |
40274 | Вход id | | word |
40275 | Вход id sting | | string(16) |
40283 | Dc ток | | word |
40284 | Dc напряжение | | word |
40285 | Dc мощность | | word |
40288 | Timestamp | | dword |
40290 | Temperature | | smallint |
40292 | Module events | | dword |
40294 | Вход id | | word |
40315 | Length of basic storage controls | | word |
40316 | Setpoint for maximum charge. Additional fronius description: reference value for maximum charge and discharge. Multiply this value by inwrte to define maximum charging and outwrte to define maximum discharging. Every rate between this two limits is allowed. Note that inwrte and outwrte can be negative to define ranges for charging and discharging only | | word |
40317 | Setpoint for maximum charging rate. Default is maxcharte | | word |
40318 | Setpoint for maximum discharge rate. Default is maxdischarte | | word |
40321 | Setpoint for minimum reserve for storage as a percentage of the nominal maximum storage | | word |
40322 | Токly available energy as a percent of the capacity rating | | word |
40323 | State of charge (chastate) minus storage reserve (minrsvpct) times capacity rating (ahrrtg) | | word |
40324 | Internal battery напряжение | | word |
40326 | Percent of max discharge rate. Additional fronius description: defines maximum discharge rate. If not used than the default is 100 and wchamax defines max. Discharge rate. See wchamax for details | | smallint |
40327 | Percent of max charging rate. Additional fronius description: defines maximum charge rate. If not used than the default is 100 and wchamax defines max. Charge rate. See wchamax for details | | smallint |