Avaya MERLIN 1030. Параметры соединения и формат данных SMDR/CDR


Данные ниже соответствуют только программе Advanced PBX Data Logger и могут быть не применимы для других программных продуктов.

Avaya Merlin

PBX Limitations

100 records queue
15 digits for dialed numbers
CAS can't run in parralel with Merlin Legend Reporter (only one serial available)
inside calls are not recorded
on power failure the calls on PBX buffer are lost

Configuration

You must login as System Manager in order to change the following:

SMDR Calls Recorded on Call Report: Options->SMDr->Call Report>Selector In/Out->Enter->Back->Back
SMDR UDP Calls Recorded on Call Report: Options->SMDR->UDP->Select Log Incoming/Outgoing->Enter->Back->Back
SMDR Call Length: Options->SMDR->Call Length->Drop->0 (seconds)->Enter->Back->Back
SMDR Call Report Format: Options->SMDR->Format->Select ISDN SMDR->Enter->Back->Back
SMDR Account Code Format: Options->SMDR->Auth Code->Select Authorization Code->Enter->Back->Back
SMDR Talk Time: Options->SMDR->TalkTime->Select Enable->Enter->Back->Back

Further information can be found in Avaya Merlin Reference Manual at pages: 758-773.

Данные, извлекаемые PBX Data Logger

ОписаниеТип данныхИмя колонки
Время звонкаdatetimeCALL_TIME
ТелефонstringDIALED_PHONE
НаправлениеstringDIRECTION
Длительность звонкаdatetimeCALL_DURATION
Длительность звонка (с)integerCALL_DURATION_S
ЛинияstringFLAG2
РасширениеstringEXT
АбонентstringACC

Замечание: Продукты и компании, указанные здесь используются только для обозначение и идентификации и могут быть торговыми и/или зарегистрированными марками соответствующих компаний.